Wednesday, August 20, 2008
Analysis of ethoxylated fatty amines. Comparison of methods for the determination of molecular weight
Abstract  Specific lengths of the fatty and polyoxyethylene chains of ethoxylated fatty amines are critical to their performance in         specific applications, and thus the ability to characterize these surfactants accurately is crucial. Normal-phase high-performance         liquid chromatography (HPLC) and matrixassisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry methods         were developed to determine with accuracy the molecular weight and degree of ethoxylation of ethoxylated fatty amines. Ethoxylated         fatty amines were analyzed using these methods, and comparison was made to molecular weight determinations using proton nuclear         magnetic resonance (NMR), neutralization equivalent weight, and hydroxyl value methods. Molecular weight results from normalphase         HPLC analyses were in very good agreement with MALDI-TOF results, typically varying less than one ethylene oxide unit. A reversed-phase         HPLC method was developed to determine concentrations of polyethylene glycols (PEG) and fatty homologs. PEG interfered with         molecular weight determinations by NMR, neutralization equivalent weight, and hydroxyl value methods. PEG caused no interference         with molecular weight determinations by normal-phase HPLC and MALDI-TOF methods.